What was found
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 261DF BETWEEN FRAMES 66 TO 68 & -Y765 TO Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, TABLE 103.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 261DF BETWEEN FRAMES 66 TO 68 & -Y765 TO Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, TABLE 103.