What was found
SY6 CHECK - CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 67+15" TO 69, S23R, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SY6 CHECK - CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 67+15" TO 69, S23R, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.