What was found
2S CHECK - AREA OF DELAMINATION ON FLOOR PANEL 231CF BETWEEN FRAMES 20 TO 24, Z-500 & BETWEEN Y765 TO Y254. REPLACED FLOOR PANEL IAW IRM 9701, REV G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - AREA OF DELAMINATION ON FLOOR PANEL 231CF BETWEEN FRAMES 20 TO 24, Z-500 & BETWEEN Y765 TO Y254. REPLACED FLOOR PANEL IAW IRM 9701, REV G.