What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON DUMMY RAIL BETWEEN FR12 TO FR16, Y503. REPLACED DUMMY RAIL BETWEEN FR12 TO FR16, Y503 IAW SRM 51-72-11 & DWG D53110984.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON DUMMY RAIL BETWEEN FR12 TO FR16, Y503. REPLACED DUMMY RAIL BETWEEN FR12 TO FR16, Y503 IAW SRM 51-72-11 & DWG D53110984.