What was found
2S CHECK, CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 67+10" - 70, S23R, -Y512. REPLACED FLOOR SUPOPRT IAW SRM 51-72-11 & DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK, CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 67+10" - 70, S23R, -Y512. REPLACED FLOOR SUPOPRT IAW SRM 51-72-11 & DWG D53472780.