What was found
2S CHECK, CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 67+15" & 69, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11, DWG D53472089 & D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK, CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 67+15" & 69, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11, DWG D53472089 & D53472780.