What was found
2S CHECK - DELAMINATION FOUND ON FLOOR PANEL 241HF BETWEEN FRAMES 36 TO 42 & Y1292 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8A, FIG 209.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - DELAMINATION FOUND ON FLOOR PANEL 241HF BETWEEN FRAMES 36 TO 42 & Y1292 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8A, FIG 209.