What was found
DURING 2S CHECK, CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 68 TO 69, Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 68 TO 69, Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.