What was found
DURING C4 CHECK, CORROSION FOUND AT R3 EMERGENCY EXIT DOORWAY INTERNAL FLOORBEAM AT BS 1340, S17R. REPAIRED IAW SRM 51-40-02, DWG 146N8322 & 146N6303,
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C4 CHECK, CORROSION FOUND AT R3 EMERGENCY EXIT DOORWAY INTERNAL FLOORBEAM AT BS 1340, S17R. REPAIRED IAW SRM 51-40-02, DWG 146N8322 & 146N6303,