What was found
2S CHECK DELAMINATION ON FLOOR PANEL 151GE BETWEEN FRAME 58 TO FRAME 59, STRINGER 38L TO STRINGER 35L, Y1292 TO Y765. REPLACED FLOOR PANEL 151GE IAW A319 SRM 53-02-00, FIG 209 & IRM 9701, REV G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK DELAMINATION ON FLOOR PANEL 151GE BETWEEN FRAME 58 TO FRAME 59, STRINGER 38L TO STRINGER 35L, Y1292 TO Y765. REPLACED FLOOR PANEL 151GE IAW A319 SRM 53-02-00, FIG 209 & IRM 9701, REV G.