What was found
C4 CHECK, LEVEL 2 GALVANIC CORROSION ON FLOOR BEAM AT BS 654 BETWEEN RBL 55 TO RBL 58. REPAIRED FLOOR BEAM AT BS 654 BETWEEN RBL 55 TO RBL 58 IAW B767 SRM 53-00-51-2R, FIG 201, DETAIL 1 & 51-21-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK, LEVEL 2 GALVANIC CORROSION ON FLOOR BEAM AT BS 654 BETWEEN RBL 55 TO RBL 58. REPAIRED FLOOR BEAM AT BS 654 BETWEEN RBL 55 TO RBL 58 IAW B767 SRM 53-00-51-2R, FIG 201, DETAIL 1 & 51-21-00.