Service difficulty report · Oil System · Airbus A319112

Difficulty date
December 30, 2013
Submitted
December 31, 2013
Operation
Air carrier
Aircraft
N741UW
Make and model
Airbus A319112
Aircraft serial
1269
Aircraft time
37,136 hours, 22,293 cycles
Part
Oil System
Condition
Overserviced
Location
Apu
Stage of operation
CL
How discovered
O
Nature of condition
W, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FUME SMELL IN ACFT CABIN AFTER TAKEOFF. STARTED APU & SELECTED APU BLEED. FUMES WENT AWAY, FAINT DIRTY SOCK SMELL. REMOVED BOTH ENG SPINNERS & INSPECTED FOR OIL, NONE NOTED. REINSTALLED SPINNERS IAW AMM 72-21-00. FOUND APU INLET SEAL INSTALLED UPSIDE DOWN, REMOVED & REINSTALLED TO CORRECT POSITION. FOUND APU OVER SERVICED, SERVICED TO PROPER LEVEL. ACCOMPLISHED JOB CARD 26L00021001. NO FAULTS NOTED, AIRCRAFT OK FOR SERVICE.