What was found
C4 CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOOR STRUCTURE CHORD BETWEEN BS 1260 TO BS 1280, WL 208.1, LBL 62. REPAIRED CHORD CREASE BEAM ANGLE, FLOOR SUPPORT, BETWEEN BS 1260 TO BS 1280, WL 208.1, LBL 62 IAW SRM 51-10-02 & 53-60-13-1A.