What was found
C4 CHECK LEVEL 2 EXFOLIATION CORROSION ON AFT DECK PLATE LOWER RE ENFORCEMENT ANGLE AT BS 1714, RBL 36. REPLACED AFT DECK PLATE LOWER RE ENFORCEMENT ANGLE AT BS 1714, RBL 36 IAW SRM 51-20-01-0G, 53-00-51-1A, 51-30-01-0G, 51-40-02-0G & DWG 146N5240.