Service difficulty report · Valve · Boeing 737401

Difficulty date
February 1, 2014
Submitted
February 3, 2014
Operation
Air carrier
Aircraft
N409US
Make and model
Boeing 737401
Aircraft serial
23879
Aircraft time
68,896 hours, 46,150 cycles
Part
Valve
Part number
69291425
Condition
Faulty
Location
Ac System
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
G, B, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CLIMBING THROUGH FL180, CABIN ALTITUDE PRESS RAPIDLY INCREASED TO 15,000 FEET. CABIN ALTITUDE WARNING LIGHT ILLUMINATED & HORN SOUNDED. PAX OXYGEN MASKS DROPPED. UNABLE TO ESTABLISH PRESS IN AUTO OR STANDBY, AN EMERGENCY WAS DECLARED. FLIGHT RETURNED TO FIELD AT CLT & LANDED WITHOUT INCIDENT. FOUND THE AIR CONDITIONING GND SERVICE VLV REMAINING OPEN, REPLACED VLV IAW AMM 21-21-15. OPERATIONS CHECKED GOOD, ACFT PRESSURIZATION TESTED GOOD AT THIS TIME. REPLACED OXYGEN GENERATORS & REPACKED MASKS.