What was found
C1 CHECK DELAMINATION ON LT HORIZONTAL SKIN UPPER SURFACE INBD PANEL AT STAB STATION 224.249 APPROXIMATELY 6 INCHES FROM LE. REPLACED LT HORIZONTAL UPPER INBD PANEL IAW SRM 51-40-02, EA 105500 & EA 105582.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C1 CHECK DELAMINATION ON LT HORIZONTAL SKIN UPPER SURFACE INBD PANEL AT STAB STATION 224.249 APPROXIMATELY 6 INCHES FROM LE. REPLACED LT HORIZONTAL UPPER INBD PANEL IAW SRM 51-40-02, EA 105500 & EA 105582.