What was found
A CHECK 2 SOFT SPOTS IN FWD GALLEY MID FLOOR PANEL BETWEEN FRAME 20 TO FRAME 22, STRINGER 23L TO STRINGER 23R. REPLACED FWD GALLEY MID FLOOR PANEL BETWEEN FRAME 20 TO FRAME 22, STRINGER 23L TO STRINGER 23R IAW MM 53-12-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A CHECK 2 SOFT SPOTS IN FWD GALLEY MID FLOOR PANEL BETWEEN FRAME 20 TO FRAME 22, STRINGER 23L TO STRINGER 23R. REPLACED FWD GALLEY MID FLOOR PANEL BETWEEN FRAME 20 TO FRAME 22, STRINGER 23L TO STRINGER 23R IAW MM 53-12-12.