What was found
ON DESCENT OUT OF 26,000 FT, WITH N1 AT 76%, SMALL COMPRESSOR STALLS ON LT ENG. ENG GAUGES FLUCTUATED ON LT ENG N1 & N2, EGT NORMAL. PULLED ENG TO IDLE, ALL INDICATIONS NORMAL. LEVEL OFF AT 10,000 FEET, PUSHED BOTH ENGS UP AT 75%, ENG COMPRESSOR STALLED, PULLED TO IDLE, NORMAL INDICATION AT IDLE. LANDED WITH ENG AT IDLE. ACCOMPLISHED BORESCOPE FOR STALL, SURGE, ON NR 1 ENG IAW AMM 72-00-00-216-062-C00, ITEM N 3, PAGE 14. NO DAMAGE FOUND. ACCOMPLISHED ENG NR 1 TROUBLESHOOTING IAW AMM 71-00-43-101, BLOCK 1 THRU BLOCK 11. R & R ENG NR 1 CIT SENSOR IAW AMM 73-21-02-404-010. ACCOMPLISHED POWER ASSURANCE CHECK IAW AMM 71-00-00-725. NO COMPRESSOR STALLS NOTED.