S2 CHECK LEVEL 2 SURFACE CORROSION ON CABIN FLOORBEAM AT FRAME 66, Z-500, Y765. REPLACED CABIN FLOORBEAM AT FRAME 66, Z-500, Y765 IAW SRM 51-42-11, 51-72-11 & DWG D53472831 & D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
S2 CHECK LEVEL 2 SURFACE CORROSION ON CABIN FLOORBEAM AT FRAME 66, Z-500, Y765. REPLACED CABIN FLOORBEAM AT FRAME 66, Z-500, Y765 IAW SRM 51-42-11, 51-72-11 & DWG D53472831 & D53472815.