What was found
C4 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT CHANNEL BETWEEN BS 324 TO BS 345, LBL 19. REPLACED FLOOR SUPPORT CHANNEL BETWEEN BS 324 TO BS 345, LBL 19 IAW SRM 51-10-02 & 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT CHANNEL BETWEEN BS 324 TO BS 345, LBL 19. REPLACED FLOOR SUPPORT CHANNEL BETWEEN BS 324 TO BS 345, LBL 19 IAW SRM 51-10-02 & 51-40-02.