What was found
C4 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT CHANNEL AT BS 395 BETWEEN RBL 47 TO RBL 55. REPLACED FLOOR SUPPORT CHANNEL AT BS 395 BETWEEN RBL 47 TO RBL 55 IAW SRM 51-40-02 & 51-40-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT CHANNEL AT BS 395 BETWEEN RBL 47 TO RBL 55. REPLACED FLOOR SUPPORT CHANNEL AT BS 395 BETWEEN RBL 47 TO RBL 55 IAW SRM 51-40-02 & 51-40-05.