What was found
C4 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT STRUCTURE BETWEEN BS 720 TO BS 740, LBL 63. REPLACED FLOOR SUPPORT BETWEEN BS 720 TO BS 740, LBL 63 IAW SRM 51-40-02, 51-21-01, 51-10-02 & 51-21-15.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT STRUCTURE BETWEEN BS 720 TO BS 740, LBL 63. REPLACED FLOOR SUPPORT BETWEEN BS 720 TO BS 740, LBL 63 IAW SRM 51-40-02, 51-21-01, 51-10-02 & 51-21-15.