What was found
C4 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT FITTING BETWEEN BS 297 TO BS 310, RBL 45. REPLACED FLOOR SUPPORT FITTING BETWEEN BS 297 TO BS 310, RBL 45 IAW SRM 51-40-02 & DWG 141N5161.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT FITTING BETWEEN BS 297 TO BS 310, RBL 45. REPLACED FLOOR SUPPORT FITTING BETWEEN BS 297 TO BS 310, RBL 45 IAW SRM 51-40-02 & DWG 141N5161.