What was found
S2 CHECK CRACK IN FLOOR SUPPORT BEAM AT FRAME 35.1, STRINGER 35R. REPLACED FLOOR SUPPORT BEAM AT FRAME 35.1, STRINGER 35R IAW SRM 51-42-11 & DWG C4 D53235151.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
S2 CHECK CRACK IN FLOOR SUPPORT BEAM AT FRAME 35.1, STRINGER 35R. REPLACED FLOOR SUPPORT BEAM AT FRAME 35.1, STRINGER 35R IAW SRM 51-42-11 & DWG C4 D53235151.