Service difficulty report · Computer · Airbus A319112

Difficulty date
June 11, 2014
Submitted
June 17, 2014
Operation
Air carrier
Aircraft
N710UW
Make and model
Airbus A319112
Aircraft serial
1019
Aircraft time
43,106 hours, 24,439 cycles
Part
Computer
Part number
87292325V06
Part serial
324
Condition
Faulted
Location
Cabin Pressure
Part time
64,959 hours, 27,918 cycles
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB OUT, CREW RECEIVED AN ECAM VENT SKIN VALVE FAULT. RAN ECAM, UNABLE TO PRESSURIZE. FLIGHT RETURNED TO FIELD & LANDED WITHOUT INCIDENT. FOUND AEVC FAULTY IAW TSM 21-26-34. REMOVED & INSTALLED SERVICEABLE AEVC AMM 21-26-34-400-001A. OPS TEST OF VENTILATION SYS OF AVIONICS EQUIPMENT, TESTED GOOD, NO FAULTS.