What was found
C11 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FRAME 69 TO 70, -Y 765. REPLACED FLOOR SUPPORT BETWEEN FRAME 69 TO 70, -Y 765 IAW SRM 53-00-14, FIG 102 & SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FRAME 69 TO 70, -Y 765. REPLACED FLOOR SUPPORT BETWEEN FRAME 69 TO 70, -Y 765 IAW SRM 53-00-14, FIG 102 & SRM 51-42-11.