What was found
C1 CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM UPPER SURFACE AT FRAME 67, Y 1292. REPLACED FLOORBEAM UPPER SURFACE AT FRAME 67, Y 1292 IAW SRM 51-72-11 & DWG D53472000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C1 CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM UPPER SURFACE AT FRAME 67, Y 1292. REPLACED FLOORBEAM UPPER SURFACE AT FRAME 67, Y 1292 IAW SRM 51-72-11 & DWG D53472000.