What was found
C11 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT BETWEEN BS 333.45 TO 345 LBL 58.22. REPLACED FLOOR SUPPORT IAW SRM 51-10-02 & 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT BETWEEN BS 333.45 TO 345 LBL 58.22. REPLACED FLOOR SUPPORT IAW SRM 51-10-02 & 51-40-02.