What was found
C11 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT BETWEEN BS 347.7 TO 395 & BETWEEN BL0 TO RBL 24.75. REPLACED FLOOR SUPPORT IAW SRM 53-00-51 FIG 101 & 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT BETWEEN BS 347.7 TO 395 & BETWEEN BL0 TO RBL 24.75. REPLACED FLOOR SUPPORT IAW SRM 53-00-51 FIG 101 & 51-40-02.