What was found
C1 CHECK DELAMINATION ON RT ELEVATOR UPPER SKIN PANEL AT APPROX 2 INCHES INBD OF STAB STATION 113.068. REPAIRED RT ELEVATOR UPPER SKIN PANEL IAW SRM 51-70-17 & EA 106064.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C1 CHECK DELAMINATION ON RT ELEVATOR UPPER SKIN PANEL AT APPROX 2 INCHES INBD OF STAB STATION 113.068. REPAIRED RT ELEVATOR UPPER SKIN PANEL IAW SRM 51-70-17 & EA 106064.