What was found
2S CHECK LEVEL 2 INTERGRANULAR CORROSION ON SHEAR TIE BETWEEN FRAME 69 TO 70, STRINGER 23L, Z-500, Y1611. REPLACED SHEAR TIE IAW SRM 52-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK LEVEL 2 INTERGRANULAR CORROSION ON SHEAR TIE BETWEEN FRAME 69 TO 70, STRINGER 23L, Z-500, Y1611. REPLACED SHEAR TIE IAW SRM 52-72-11.