What was found
2S CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FRAME 66, Z-500, -Y1292. REPLACED FLOORBEAM IAW SRM 51-72-11 & DWG D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FRAME 66, Z-500, -Y1292. REPLACED FLOORBEAM IAW SRM 51-72-11 & DWG D53472815.