What was found
WEEKLY VISIT 6 INCH CRACK ON INTERCOSTAL AT BS 1440, STRINGER 24R. REPLACED INTERCOSTAL IAW SRM 51-40-02 & DWG 146N8545.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WEEKLY VISIT 6 INCH CRACK ON INTERCOSTAL AT BS 1440, STRINGER 24R. REPLACED INTERCOSTAL IAW SRM 51-40-02 & DWG 146N8545.