What was found
EPSU 13WL SHOWS UNIT FAULT AFTER TEST. REPLACED 13WL EPSU & BATTERY IAW AMM 33-51-38 401. OPERATIONS TESTED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EPSU 13WL SHOWS UNIT FAULT AFTER TEST. REPLACED 13WL EPSU & BATTERY IAW AMM 33-51-38 401. OPERATIONS TESTED NORMAL.