What was found
RON RT HYD BAY COMPARTMENT AFT WALL KEEL BEAM ATTACH ANGLE CRACKED BETWEEN 2 LOCK FASTENER. R & R CRACKED ANGLE WITH NEW ANGLE IAW SRM 51-42-00 & DWG D53370500.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RON RT HYD BAY COMPARTMENT AFT WALL KEEL BEAM ATTACH ANGLE CRACKED BETWEEN 2 LOCK FASTENER. R & R CRACKED ANGLE WITH NEW ANGLE IAW SRM 51-42-00 & DWG D53370500.