What was found
EMERGENCY LIGHTING OPERATIONS TEST 33-51-00-710-001 REVEALS EXTERNAL LOAD SHORT CIRCUIT AT AFT EPSU 13WL. ISOLATED TO DEFECTIVE L2 DOOR SLIDE INTEGRAL LIGHTS IAW TSM 33-51-00-810-808 A. REPLACED L2 DOOR SLIDE IAW JOB CARD 26L00025011.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTING OPERATIONS TEST 33-51-00-710-001 REVEALS EXTERNAL LOAD SHORT CIRCUIT AT AFT EPSU 13WL. ISOLATED TO DEFECTIVE L2 DOOR SLIDE INTEGRAL LIGHTS IAW TSM 33-51-00-810-808 A. REPLACED L2 DOOR SLIDE IAW JOB CARD 26L00025011.