S1 CHECK, LEVEL 2 EXFOLIATION CORROSION ON RT SILL PLATE AT FRAME 68, STRINGER 23R, Z-500. REPAIRED RT SILL PLATE AT FRAME 68, STRINGER 23R, Z-500 IAW SRM 53-41-14-201.