What was found
SYS 6 CHECK, LEVEL 2 EXFOLIATION CORROSION ON SHEAR TIE BETWEEN FRAME 68 TO 69, STRINGER 23L, Z-500. REPLACED SHEAR TIE IAW SRM 51-42-11 & DWG D53471124.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SYS 6 CHECK, LEVEL 2 EXFOLIATION CORROSION ON SHEAR TIE BETWEEN FRAME 68 TO 69, STRINGER 23L, Z-500. REPLACED SHEAR TIE IAW SRM 51-42-11 & DWG D53471124.