What was found
PIT - DURING Q-3 CHECK INSPECTION, FOUND SEVERAL CRACKS IN LONGERON 17L AT STATION 280. REPLACED LONGERON AND SPLICED PER SRM 53-02 FIG 2 AND USAIR EA NR 2893. (Z)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-3 CHECK INSPECTION, FOUND SEVERAL CRACKS IN LONGERON 17L AT STATION 280. REPLACED LONGERON AND SPLICED PER SRM 53-02 FIG 2 AND USAIR EA NR 2893. (Z)