What was found
PIT - DURING Q-3 CHECK INSPECTION, FOUND .5 INCH AND .75 INCH CRACK IN STATION 1452 LONGERONS 3R AND 3L. MANUAL NEW CLIP AND REPAIRED PER SRM 53-03. (Z)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-3 CHECK INSPECTION, FOUND .5 INCH AND .75 INCH CRACK IN STATION 1452 LONGERONS 3R AND 3L. MANUAL NEW CLIP AND REPAIRED PER SRM 53-03. (Z)