As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING Q-4 CHECK, INSPECTION FOUND CORROSION LEVEL I AREA PREVIOUSLY REWORKED STA 1338 RT LAV AREA FLOORBEAM. CORROSION TASK NR C58-53300. REPLACED TOP ANGLE AND INSTALLED DOUBLER REPAIRS, WEB AND FITTING TYPICAL REPAIR 53-10-14 AND SRM 53-05 FIG 72. (W)