What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION ON AFT CARGO FLOOR STRINGERS, BS 775 AT LBL 2, 7, AND 12 RBL 2, 7, (5 PLACES). REPAIRED PER TR 53-10-06. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (Z)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION ON AFT CARGO FLOOR STRINGERS, BS 775 AT LBL 2, 7, AND 12 RBL 2, 7, (5 PLACES). REPAIRED PER TR 53-10-06. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (Z)