PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND 1 INCH SKIN CRACK AT CUSP MEMBRANE AT STATION 604 LONGERON 18R STATION 598 18L. INSTALLED SPLICE REPAIR PER SRM 53-05 FIG 96. (W)