PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND LEVEL I CORROSION AT CUSP MEMBRANE AT STATION 945 RT SIDE. REMOVED CORRODED SECTION OF MEMBRANE AND INSTALLED SPLICE REPAIR PER SRM 53-05 FIG 96. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND LEVEL I CORROSION AT CUSP MEMBRANE AT STATION 945 RT SIDE. REMOVED CORRODED SECTION OF MEMBRANE AND INSTALLED SPLICE REPAIR PER SRM 53-05 FIG 96. (W)