What was found
PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND .035 GAUGE 7 INCH LONG IN VERTICAL STAB AT STA ZV133 LT SIDE. INSTALLED DOUBLER REPAIR PER SRM 35-01 FIG 2. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND .035 GAUGE 7 INCH LONG IN VERTICAL STAB AT STA ZV133 LT SIDE. INSTALLED DOUBLER REPAIR PER SRM 35-01 FIG 2. (W)