What was found
PIT - DURING Q-4 CHECK INSPECTION, FOUND LEVEL I CORROSION RT LAV STATION 996 WEB. CLEANED CORROSION AND INSTALLED DOUBLER PER SRM 53-05 FIG 72. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4 CHECK INSPECTION, FOUND LEVEL I CORROSION RT LAV STATION 996 WEB. CLEANED CORROSION AND INSTALLED DOUBLER PER SRM 53-05 FIG 72. (W)