What was found
PIT - DURING Q-2 INSPECTION, FOUND A 1 INCH BY 100 INCH DEEP DENT AT STATION 408 LONGERON 17 LEFT. INSTALLED INTERNAL DOUBLER PER SRM 53-04 FIG 38 VIEW G. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-2 INSPECTION, FOUND A 1 INCH BY 100 INCH DEEP DENT AT STATION 408 LONGERON 17 LEFT. INSTALLED INTERNAL DOUBLER PER SRM 53-04 FIG 38 VIEW G. (W)