What was found
PIT - DURING Q-2 INSPECTION, FOUND A 1.75 INCH CRACK BETWEEN STATION 1287 AND STATION 1309 LEFT SIDE CUSP MEMBRANE. MANUFACTURED NEW SECTION OF CUSP MEMBRANE AND ACCOMPLISHED SPLICE REPAIR PER SRM 53-05 FIG 97. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-2 INSPECTION, FOUND A 1.75 INCH CRACK BETWEEN STATION 1287 AND STATION 1309 LEFT SIDE CUSP MEMBRANE. MANUFACTURED NEW SECTION OF CUSP MEMBRANE AND ACCOMPLISHED SPLICE REPAIR PER SRM 53-05 FIG 97. (W)