What was found
PIT - DURING Q-2 INSPECTION, FOUND LEVEL I CORROSION AT STATION 1338 AFT CARGO AREA BETWEEN LONGERONS 28L AND 28R. REMOVED CORROSION, CLEANED AND TREATED. INSTALLED REPAIR DOUBLERS PER SRM 53-03 FIG 3 PER USAIR TYPICAL REPAIR 53-30-10. (W)