What was found
PIT - DURING Q-2 INSPECTION, FOUND LEVEL I CORROSION AT STATION 1322 BETWEEN AFT GALLEY AND AFT LAV CENTER AISLE. REMOVED CORRODED AREA AND INSTALLED FILLER AND REPAIR ANGLE PER USAIR TYPICAL REPAIR 53-10-19. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-2 INSPECTION, FOUND LEVEL I CORROSION AT STATION 1322 BETWEEN AFT GALLEY AND AFT LAV CENTER AISLE. REMOVED CORRODED AREA AND INSTALLED FILLER AND REPAIR ANGLE PER USAIR TYPICAL REPAIR 53-10-19. (W)